Number | 645
|
Category | errata
|
Synopsis | 7.1.2: pulldown strength specification ambiguity
|
State | etfpassed
|
Class | errata-simple
|
Arrival-Date | Dec 23 2004
|
Originator | Shalom.Bresticker@freescale.com
|
Release | 2001b
|
Description |
A comment from Geoffrey Coram prompted this: 7.1.2 says, "The pullup gate can have only strength1 specification; strength0 specification shall be optional. The pulldown gate can have only strength0 specification; strength1 specification shall be optional. See 7.8 for more details." The intent is to say that it is permissible to have no strength specification, or only strength1 (for pullup, reverse for pulldown), or both strength1 and strength0. This is in contrast to other gates, where you specify either no strength or both of them, but you may not specify only one. The wording is murky here. -- Shalom Bresticker Shalom.Bresticker @freescale.com Design & Verification Methodology Tel: +972 9 9522268 Freescale Semiconductor Israel, Ltd. Fax: +972 9 9522890 POB 2208, Herzlia 46120, ISRAEL Cell: +972 50 5441478 [ ]Freescale Internal Use Only [ ]Freescale Confidential Proprietary |
Fix |
In 7.1.2, CHANGE "The pullup gate can have only strength1 specification; strength0 specification shall be optional. The pulldown gate can have only strength0 specification; strength1 specification shall be optional. See 7.8 for more details." TO “The pullup gate shall have one of the following: no strength specification, only a strength1 specification, or both strength1 and strength0 specifications. The pulldown gate shall have one of the following: no strength specification, only a strength0 specification, or both strength1 and strength0 specifications. See 7.8 for more details."” |
Audit-Trail |
Fix replaced by Shalom.Bresticker@freescale.com on Sun Dec 26 00:27:44 2004 In 7.1.2, CHANGE "The pullup gate can have only strength1 specification; strength0 specification shall be optional. The pulldown gate can have only strength0 specification; strength1 specification shall be optional. See 7.8 for more details." TO "The pullup gate may have a strength1 specification without a strength0 specification; the strength0 specification shall be optional. The pulldown gate may have a strength0 specification without a strength1 specification; the strength1 specification shall be optional. See 7.8 for more details." Fix replaced by pieper@synopsys.com on Mon Feb 7 09:31:33 2005 In 7.1.2, CHANGE "The pullup gate can have only strength1 specification; strength0 specification shall be optional. The pulldown gate can have only strength0 specification; strength1 specification shall be optional. See 7.8 for more details." TO “The pullup gate shall have one of the following: no strength specification, only a strength1 specification, or both strength1 and strength0 specifications. The pulldown gate shall have one of the following: no strength specification, only a strength0 specification, or both strength1 and strength0 specifications. See 7.8 for more details."” |
Unformatted |
|
Hosted by Boyd Technology