ISSUE 214

Number 214
Category errata
Synopsis 23.90: wrong comment in Figure 151?
State lrmdraft
Class errata-ptf
Arrival-DateDec 09 2002
Originator Shalom.Bresticker@motorola.com
Release 2001b: 23.90
Environment
Description

In 23.90, in Figure 151, there is a box with comments, which
says, "fetch min:typ:max delays and store in array da as
follows:
da[0]\
da[1]- typical rise delay
da[2]/
da[3]\
da[4]- typical fall delay
da[5]/
da[6]\
da[7]- typical turn-off delay
da[8]/

Now I don't understand PLI or even C all that well,
but so far as I can see, da[0] is a min rise delay, da[1]
is a typ rise delay, da[2] is a max rise delay, etc.

If so, the words "typical" in the comment box should be
replaced by "min:typ:max", in three places.
Fix
Replace "typical" by "min:typ:max" in the three places.